The MSI-3430 crane scale is perfect for light to medium applications. This module has the industry standard weighing capabilities of the past Challenger designs. Viewing is enhanced with the ultrabright LED display with high digits with a resolution up to 10,000 and a loading accuracy of 0.1%. With its long-lasting 6-volt rechargeable battery, the products operating time can now last 50 plus hours. With all new NEMA 4/ IP65 levels Challenger packaging. Challenger products are manufactured in the USA with strict Safety Standards, the Challenger continually sustains a minimum score of 200% safe and 500% ultimate load ratings. Net/Gross, Tare, Auto-Off, Peak Hold, Set Points and Load Totalizing are just a few of the advanced crane weighing applications that are available through standard programmable controls. Additional options available are application versatility where RF remote control, RF remote display and/or audible alarms on set point activation. An electronics retrofit kit is also available for customers who wish to upgrade their existing MSI-3260 or MSI-3360 Challengers to the new generation MSI-3460.
Capacity | 500 lb (250 kg) |
---|---|
Readability | 0.2 lb (0.1 kg) |
Accuracy | ± (0.1% +1d) of applied load |
Resolution | 2000 to 3750 d standard |
Enclosure | NEMA 4, IP65, powder coated cast aluminum |
Lifting Eye & Hook | Crosby or equivalent with 360° non-bearing swivel hook |
Design Overload | 200% safe / 500% ultimate |
Functions |
Power: Turns unit ON or OFF Zero: Zeros applied load up to 100% of capacity (limited range in NTEP/OIML configurations) Tare: Tares applied load and displays weight in Net mode User: Programmable as TEST, UNITS, NET/GROSS, TOTAL and PEAK HOLD |
Display | Five-digit, 1.5" (38 mm) LED with programmable brightness control |
Displayable Units | Pounds or kilograms selectable |
Annunciators | COZ, Net, Gross, Total, Peak, Low Battery, lb/kg, Motion, Setpoints, ACK IN, ACK OUT, RF |
Power | 6 volt rechargeable battery (115/230 VAC battery charger is included) |
Operating Time | Up to 80 hours between charging with typical use (less with optional RF Model Link) |
Operating Temperature | 14°F to 104°F (-10°C to 40°C) |
Auto-Off Mode | Select for 15, 30, 45, 60 minutes or Off |
Auto Sleep Mode | Power down during non-use and power up with weight change or any key press |
Service Counters | Counts number of lifts over percentage of capacity and lifts over capacity |
Calibration | Digital |
Filtering | OFF, LO, HI-1, HI-2 selectable |
Approvals | NTEP CC 86-021 |